Download e-book for iPad: 2014 ASHRAE Handbook -- Refrigeration (I-P) (Ashrae Handbook by ASHRAE

By ASHRAE

ISBN-10: 1680153277

ISBN-13: 9781680153279

ISBN-10: 1936504715

ISBN-13: 9781936504718

The 2014 ASHRAE Handbook€”Refrigeration covers the refrigeration apparatus and platforms for functions except human convenience. This quantity contains info and assistance on cooling, freezing, and storing nutrition; business and scientific purposes of refrigeration; and low-temperature refrigeration; and incorporates a dual-unit CD.

CD approach requisites: home windows: CD-ROM force; 1.3 GHz or speedier processor; Microsoft home windows Vista, home windows 7, or home windows eight (62-bit and 64-big); 1 GB of RAM (2 GB recommended); Microsoft net Explorer eight or larger; Adobe Acrobat/Reader 10.0 or better; 350 MB hard-disk house. Macintosh: Mac OS X v. 10.5.8 or v. 10.6.4; 512 MB of RAM (1 GB recommended); 415 MB hard-disk area; 800 x six hundred display solution (1024 x 768 recommended); Safari four for Mac OS X v. 10.5.8, Safari four or 5.0x for Mac OS X v. 10.6.4, Safari 6.0 for Mac OS X v. 10.7.4 or v. 10.8; Firefox; Adobe Acrobat/Reader 10.0 or greater. quotation: 2014 ASHRAE Handbook

ASHRAE, based in 1894, is a world association of a few 50,000 folks. ASHRAE fulfills its undertaking of advancing heating, air flow, air con, and refrigeration to serve humanity and advertise a sustainable international via study, criteria writing, publishing, and carrying on with schooling.

The ASHRAE Handbooks are the layout regular for regulate of equipped environments with volumes on structures and kit, HVAC functions, Refrigeration and basics. each one is up to date each 4 years. as well as publishing layout tips for engineers, architects, and facility managers, we additionally put up a sequence of texts for school room use.

many of the parts we submit in include:
-Energy Modeling and Auditing
-High functionality development Design
-Psychrometrics
-Indoor Air caliber and Environmental Quality
-Data heart power Efficiency
-Noise & Vibration Control
-Humidity Control
-HVAC for Healthcare amenities

Show description

Read Online or Download 2014 ASHRAE Handbook -- Refrigeration (I-P) (Ashrae Handbook Refrigeration Systems/Applications Inch-Pound System PDF

Best ventilation & air conditioning books

Download e-book for kindle: Aerobiological Engineering Handbook (McGraw Hill Handbooks) by Wladyslaw Kowalski

Remedy any development air caliber challenge a whole reference for the layout of air filtration structures and HVAC platforms utilized in houses, faculties, hospitals, laboratories, or animal amenities, this publication bargains entire descriptions of every of the most important applied sciences at the moment used for air disinfection.

Read e-book online Bauchemie für das Bachelor-Studium: Modern – Kompetent – PDF

Das Buch ist für den Studienanfänger der Studiengänge Bauingenieurwesen und Architektur konzipiert, es soll aber auch dem Baupraktiker als nützliches Nachschlagewerk dienen. In kompakter shape werden sowohl Grundlagen als auch spezielle Kenntnisse zu Baustoffen und baurelevanten Prozessen vermittelt. Exemplarisch wird eine Auswahl von Verbindungen, Stoffen, Reaktionen und Prozessen unter dem Gesichtspunkt ihrer Praxisrelevanz für das Bauwesen sowie ökologischer Aspekte getroffen.

Download PDF by Alexander V. Dimitrov: Energy modeling and computations in the building envelope

Strength Modeling and Computations within the construction Envelope instills a deeper realizing of the power interactions among constructions and the surroundings, according to the research of move tactics working within the construction envelope elements on the microscopic point. the writer: Proposes a generalized physics version that describes those interactions on the microscopic point through the macroscopic features of the construction envelope offers mathematical types that make the most of classical analytical instruments and will be used to accomplish quantitative predictions of the implications of the power interactions finds easy-to-apply engineering tools about the layout and inspection of the development envelope, bearing in mind the consequences of power at the envelope strength Modeling and Computations within the construction Envelope offers accomplished assurance of this environmentally and economically very important subject, from the physics of power move to its numerical estimation.

Download PDF by A. Omarini: Retail Banking: Business Transformation and Competitive

The area of retail banking is altering. whereas formerly a in simple terms money-making entity, the has introduced social accountability onto its time table, and the floor ideas for fulfillment have altered. conventional convictions, ideas and values that experience stimulated all banking enterprise long ago are introduced into query via this shift, and banks are adopting daring thoughts with the intention to win out over opponents.

Extra resources for 2014 ASHRAE Handbook -- Refrigeration (I-P) (Ashrae Handbook Refrigeration Systems/Applications Inch-Pound System

Example text

Where multiple expansion valves with internal strainers are used at one location, a single main liquid-line strainer will protect all of these. The liquid-line strainer can be located anywhere in the line between the condenser (or receiver) and the automatic valves, preferably near the valves for maximum protection. Strainers should trap the particle size that could affect valve operation. With pilot-operated valves, a very fine strainer should be installed in the pilot line ahead of the valve.

The refrigerant level is generally controlled through a high- or low-side float control. Figure 16 represents a typical arrangement showing a low-side float control, oil return line, and heat interchanger. Circulation of refrigerant through the evaporator depends on gravity and a thermosiphon effect. A mixture of liquid refrigerant and vapor returns to the surge tank, and the vapor flows into the suction line. A baffle installed in the surge tank helps prevent foam and liquid from entering the suction line.

Subcooling liquid refrigerant to prevent flash gas at the expansion valve. The heat exchanger should be located near the condenser or receiver to achieve subcooling before pressure drop occurs. • Evaporating small amounts of expected liquid refrigerant returning from evaporators in certain applications. Many heat pumps incorporating reversals of the refrigerant cycle include a suctionline accumulator and liquid-suction heat exchanger arrangement to trap liquid floodbacks and vaporize them slowly between cycle reversals.

Download PDF sample

2014 ASHRAE Handbook -- Refrigeration (I-P) (Ashrae Handbook Refrigeration Systems/Applications Inch-Pound System by ASHRAE


by Anthony
4.2

Rated 4.78 of 5 – based on 32 votes